Gas Fireplace Cleaning in La Puente

Request Gas Fireplace Cleaning

Scope of the Job

Most gas fireplaces in tract houses are sealed direct-vent units: a box with fixed glass and a pipe that leaves through the wall or up the chase. Once a year the glass comes off, the pilot and burner are cleaned, the ember material goes back where the manual's diagram puts it, and the outside termination is cleared of nests. We finish with a carbon monoxide reading.

Fixed glass removed, cleaned and resealed
Pilot hood and burner ports cleared
Logs and embers placed per the diagram
Outside termination checked for nests
Carbon monoxide reading at the end

What Builds Up in a Gas Unit

Gas leaves less behind than wood, but it is not nothing. Dust and pet hair pulled in with the burner air bake onto the logs and the burner tray. Spiders build in the pilot tube over summer and starve the pilot of air. Logs that got bumped, or set back by hand after a move, start to sit in the flame, which turns it orange and lays soot on the glass and the logs. On sealed units, the inside of the glass clouds over with a pale film that soap and water will not lift. Each of those makes the fireplace look worse, and the soot and a misplaced log also mean the burner is no longer burning the gas the way it was tested to. A cleaning puts the unit back to the state its maker approved, which is also the state it was rated for heat and exhaust in.

The visit follows the unit's manual. Work starts cold and with the valve closed. The front panel and, on sealed models, the glass frame come off; the log set and ember material are lifted out piece by piece and laid on a cloth in the order they came out. The burner ports, the pilot hood and the flame sensor are cleaned. Logs go back exactly to the maker's diagram, which is printed in the manual or on a card inside the unit, and the embers are spread as specified rather than by eye. We clear the film off the glass and check the seal around its frame, and on direct-vent models we look at the vent cap outside for nests and damage. Last, we light it and watch the pilot and the main flame on high and low before the front goes back on.

Prefab Units With Gas, and Sealed Units

Two kinds of gas fireplace show up in La Puente homes. One is a factory-built wood fireplace that later had a gas log set put in it; the screen is open, a clip keeps the damper from shutting while the set burns, and the exhaust goes up the same metal pipe the wood fire used. On those, we also check that the log set is one the fireplace label allows, since many prefab makers list only certain sets, and that the clip is in place. The other kind is a sealed direct-vent unit behind fixed glass, with a two-layer vent going out the wall or the roof. Those are cleaned through the front, and the vent end outside is checked for anything blocking it. Both kinds have a label, usually on a tag behind the lower grille, and we note the model in the write-up.

Once a year suits most households, ideally before the first cold week so any part that needs replacing can be ordered without the fireplace sitting dark in December. If the unit will not light or the pilot keeps dropping out, that is a repair visit with its own page, though a dirty pilot is often the whole story and the cleaning fixes it. If you can read us the model number before the visit, any part we might need can come with us. A gas smell is a different matter altogether: nobody should be cleaning anything. Get people out, make the call to the gas company from a neighbor's yard, and book us once the line has been declared safe. For everything else, the contact page is the place to start, along with a note on whether the unit has glass in front.

How Hurley Chimney Works Handles Each Job

Label Read First

Maker and model noted before any part is chosen

Listed Parts

Caps, panels and pipe the unit was tested with

Price Before Work

Each part and its cost written down first

Photo Report

Pictures of what we found, left with you

Related Fireplace Services

Chimney Sweep

Round metal pipe or square clay tile cleared from the firebox to the cap, with the spark screen scrubbed and a creosote grade noted.

Scope and parts →

Chimney Inspection

A Level 1 look at firebox, pipe, chase top and cap, read against the maker's install manual where one can be found.

Scope and parts →

Chimney Repair

Fixes for prefab and brick chimneys alike, with metal systems repaired using parts the maker lists for that model.

Scope and parts →

Fireplace Inspection

Metal firebox, refractory panels, doors, screen, damper and the trim around them, checked against the unit's listing label.

Scope and parts →

Fireplace Repair

Cracked panels, failed dampers, warped grates and loose doors on metal fireplaces, replaced with parts listed for the model.

Scope and parts →

Chimney Level 2 Inspection

Camera through every pipe section and a look inside the chase, for a sale, after a quake or flue fire, or with a fuel switch.

Scope and parts →

Chimney Cap Installation

Terminations made for your pipe brand and diameter, or a measured cap for brick flues, each with a spark screen.

Scope and parts →

Chimney Flashing Repair

Roof seals renewed where a framed chase or brick stack meets the shingles and rain has found a path past the old metal.

Scope and parts →

Chimney Masonry Repair

Brick, mortar and stone work on masonry stacks and on the veneer faces built around prefab fireplaces.

Scope and parts →

Chimney Rebuilds

A failed brick stack relaid, or a rotted framed chase reframed and resided around new listed pipe.

Scope and parts →

Fireplace Cleaning

Ash, soot and glass film cleared from metal fireplaces without scratching the panels or the box lining.

Scope and parts →

Gas Fireplace Repair

Diagnosis on sealed gas fireplaces with a dead pilot, a weak flame or a remote that no longer answers.

Scope and parts →

Fireplace Remodel

New faces, mantels and hearths around metal fireboxes, kept to the clearances printed in the unit's manual.

Scope and parts →

Fireplace Inserts

Gas inserts for worn prefab boxes or brick openings, where the listing allows, each vented with its own liner.

Scope and parts →

Pellet Stove Repair

Jams, failed starts and shutdowns on freestanding and insert pellet units, followed back to the part at fault.

Scope and parts →

Wood Stove Repair

Seals, baffles, firebrick and pipe on freestanding stoves and wood inserts, refitted from the stove maker's parts list.

Scope and parts →

Gas Logs

Log sets for wood-burning prefab boxes, fitted only when the fireplace manual allows gas logs in that model.

Scope and parts →

Chimney Seismic Retrofit

Bracing or a lighter top for brick chimneys on older homes; metal pipe in a framed chase rarely needs it.

Scope and parts →

Chimney Crown Repair

Cracked mortar tops on brick stacks sealed or recast; framed chases use a metal lid, covered on its own page.

Scope and parts →

Dryer Vent Cleaning

Lint cleared from the duct between dryer and hood, with the flap at the outside wall or roof freed up.

Scope and parts →

Chimney Liner Installation

Stainless liners for brick flues with cracked tile, and listed replacement pipe where a prefab flue has failed.

Scope and parts →

Chimney Leak Repair

Water on a ceiling, wall or firebox floor traced to the chase top, cap, flashing or siding, then fixed at the source.

Scope and parts →

Chimney Waterproofing

Breathable repellent for brick chimneys, and sealing of siding, trim and seams on framed chases.

Scope and parts →

Chimney Damper Repair

Rusted, stuck or warped dampers on metal and brick fireplaces, mended with matching parts or a cap-mounted unit.

Scope and parts →

Chimney Chase Cover

Rusted or dished lids on framed chases replaced with stainless made to fit, sloped and edged to shed water.

Scope and parts →
Call (626) 557-0322