Chimney Rebuilds in La Puente

Request Chimney Rebuilds

Scope of the Job

On a tract house a rebuild often means the chase, not brick. Years of slow leaks rot the studs and sheathing, and the pipe inside usually needs renewing too. We strip the chase to the roofline or below, reframe it, fit new listed pipe and firestops, and close it with siding or stucco to match. Brick stacks are relaid with steel reinforcing. Permits are pulled where the city asks.

Rotted chase framing and sheathing replaced
New listed pipe and firestops inside the new chase
Siding or stucco matched to the house
Brick stacks relaid with steel reinforcing
City permits filed where required

When the Top of the Chimney Has to Come Down

Brick chimneys usually fail from the top. The part above the roof gets the most rain, the most sun and, in a quake, the most whip, and that is where we find bricks you can lift out by hand, joints washed out deep, cracks running through several courses, and stacks with a visible lean. Repointing a stack in that state holds it together for a season or two. A rebuild takes the bad section down to brick that is still holding tight and lays it up again, with a new crown and cap on top. Most rebuilds stop at or near the roof line, because the brick inside the attic and the house has stayed dry and solid. We confirm that from the attic before anything comes off, since a chimney that is cracked lower down changes the plan, the figure and sometimes the choice between the two rebuild options below.

Relaying in brick means matching what is left: brick of a similar size and color, mortar mixed to suit the old lower courses, and the same flue size, with new clay tile or a stainless liner inside. New flashing goes in as the courses rise past the roof, so a tired leak point is replaced as part of the work. New brick laid in quake country is also a chance to add steel inside the stack and ties to the roof framing, and the written scope says what we plan to include. Neighbors on the older streets of La Puente and Covina often want the stack to look as it did, and that is usually possible. When the original brick is a blend that is no longer made, we show you the closest options against the old wall before ordering, so the color question is settled before the first course goes down.

The Lighter Option: A Framed Top and a Metal Chimney

There is a second way to rebuild, and it sits close to this company's daily work. Instead of laying new brick above the roof, the old stack comes down to the roof line or just below, and a wood-framed chase is built in its place, clad to match the house, with a listed metal chimney inside and a chase lid and cap on top. The firebox below stays, connected to the new metal flue in a way its listing allows. On some fireplaces that connection is not possible, and we tell you if yours is one of them before anything is priced. A framed top weighs a small fraction of a brick one, so there is far less to fall in a strong quake, and it is easier to keep watertight. This only works where the parts are listed for that use, so it starts with the same label and manual check we do on every prefab.

Which way is right comes down to a few things: how much of the brick is sound, how the house looks from the street, whether the fireplace below burns wood or gas, and how much the owner wants the brick look kept. We put both options on paper where both are possible, each with its own figure, scope and parts list. A rebuild of either kind may need a city permit, and the scope says so where it does. If the chimney is being looked at because of quake damage, the seismic retrofit page covers bracing and straps for stacks that are still sound enough to keep. For a sale, the up-to-code page explains how we write a rebuild against an inspector's note. Book a visit through the contact page and mention whether you have seen loose brick on the roof or in the yard.

How Hurley Chimney Works Handles Each Job

Label Read First

Maker and model noted before any part is chosen

Listed Parts

Caps, panels and pipe the unit was tested with

Price Before Work

Each part and its cost written down first

Photo Report

Pictures of what we found, left with you

Related Fireplace Services

Chimney Sweep

Round metal pipe or square clay tile cleared from the firebox to the cap, with the spark screen scrubbed and a creosote grade noted.

Scope and parts →

Chimney Inspection

A Level 1 look at firebox, pipe, chase top and cap, read against the maker's install manual where one can be found.

Scope and parts →

Chimney Repair

Fixes for prefab and brick chimneys alike, with metal systems repaired using parts the maker lists for that model.

Scope and parts →

Fireplace Inspection

Metal firebox, refractory panels, doors, screen, damper and the trim around them, checked against the unit's listing label.

Scope and parts →

Fireplace Repair

Cracked panels, failed dampers, warped grates and loose doors on metal fireplaces, replaced with parts listed for the model.

Scope and parts →

Chimney Level 2 Inspection

Camera through every pipe section and a look inside the chase, for a sale, after a quake or flue fire, or with a fuel switch.

Scope and parts →

Chimney Cap Installation

Terminations made for your pipe brand and diameter, or a measured cap for brick flues, each with a spark screen.

Scope and parts →

Chimney Flashing Repair

Roof seals renewed where a framed chase or brick stack meets the shingles and rain has found a path past the old metal.

Scope and parts →

Chimney Masonry Repair

Brick, mortar and stone work on masonry stacks and on the veneer faces built around prefab fireplaces.

Scope and parts →

Fireplace Cleaning

Ash, soot and glass film cleared from metal fireplaces without scratching the panels or the box lining.

Scope and parts →

Gas Fireplace Cleaning

Burner, pilot, logs and fixed glass serviced on sealed gas units, with the outside vent termination looked at too.

Scope and parts →

Gas Fireplace Repair

Diagnosis on sealed gas fireplaces with a dead pilot, a weak flame or a remote that no longer answers.

Scope and parts →

Fireplace Remodel

New faces, mantels and hearths around metal fireboxes, kept to the clearances printed in the unit's manual.

Scope and parts →

Fireplace Inserts

Gas inserts for worn prefab boxes or brick openings, where the listing allows, each vented with its own liner.

Scope and parts →

Pellet Stove Repair

Jams, failed starts and shutdowns on freestanding and insert pellet units, followed back to the part at fault.

Scope and parts →

Wood Stove Repair

Seals, baffles, firebrick and pipe on freestanding stoves and wood inserts, refitted from the stove maker's parts list.

Scope and parts →

Gas Logs

Log sets for wood-burning prefab boxes, fitted only when the fireplace manual allows gas logs in that model.

Scope and parts →

Chimney Seismic Retrofit

Bracing or a lighter top for brick chimneys on older homes; metal pipe in a framed chase rarely needs it.

Scope and parts →

Chimney Crown Repair

Cracked mortar tops on brick stacks sealed or recast; framed chases use a metal lid, covered on its own page.

Scope and parts →

Dryer Vent Cleaning

Lint cleared from the duct between dryer and hood, with the flap at the outside wall or roof freed up.

Scope and parts →

Chimney Liner Installation

Stainless liners for brick flues with cracked tile, and listed replacement pipe where a prefab flue has failed.

Scope and parts →

Chimney Leak Repair

Water on a ceiling, wall or firebox floor traced to the chase top, cap, flashing or siding, then fixed at the source.

Scope and parts →

Chimney Waterproofing

Breathable repellent for brick chimneys, and sealing of siding, trim and seams on framed chases.

Scope and parts →

Chimney Damper Repair

Rusted, stuck or warped dampers on metal and brick fireplaces, mended with matching parts or a cap-mounted unit.

Scope and parts →

Chimney Chase Cover

Rusted or dished lids on framed chases replaced with stainless made to fit, sloped and edged to shed water.

Scope and parts →
Call (626) 557-0322