Fireplace Remodel in La Puente

Request Fireplace Remodel

Scope of the Job

Remodeling around a prefab fireplace has rules that masonry does not. The manual sets how close a mantel, trim or stone may sit to the opening, and which materials may cover the metal face. We find the manual for the model, plan the new surround within it, and if the box itself is past saving, price a new listed unit or a gas insert before anyone picks tile.

Manual clearances read before design
Tile, stone or plaster over noncombustible board
Mantel height set to the listing
Worn-out fireboxes swapped for a new listed unit
Hearth extension sized to the opening

Remodeling Around a Factory-Built Box

The fireplaces in a lot of La Puente and Diamond Bar homes still wear the face they came with: a strip of brass trim, a band of builder tile, a painted wood mantel. Updating that is one of the easier ways to change a room, and on a prefab it has rules a brick fireplace does not. The label inside the box sets the minimum distance from the opening to any wood, including the mantel shelf and the legs of a surround, and that distance grows with how far the trim sticks out. It names the materials allowed on the face right around the opening. It also shows the cooling grilles above and below the opening, which have to stay clear because they carry air through the jacket around the firebox. Cover them with stone and the outer shell runs hot against the framing. We draw the new face around those numbers first, then talk about tile, stone, plaster or wood.

A remodel also has to deal with the floor in front. On many prefabs, the hearth extension is a thin strip of tile on a non-combustible board, and its required size is on the label too. If the new design calls for a raised hearth or a wider apron, that is usually easy, but it has to be built of the right material underneath. Before any face goes on, we inspect the firebox itself, because a remodel is the wrong time to discover cracked panels or a rusted shell: once stone is set around the opening, getting to them gets harder and costlier. If the box is worn out, the remodel is the natural moment to replace it with a new listed unit or set a gas insert into it, and the new unit's label then sets the clearances the design follows. We would rather find that out before your tile is ordered.

From Sketch to Finished Fireplace

Most remodels start with a picture the owner liked and a wall to put it on. We visit, read the label, measure the opening, the existing hearth and the wall, and note the gas line or outlet if there is one. Then we lay out what the label allows: how deep a mantel can be at a given height, how close the surround legs can come, which grille openings must stay visible. From there the design is yours. Tile and thin stone over cement board are the common choices; plaster and wood work where the clearances leave room. The written figure covers taking off the old face, the new materials, the mantel, any hearth work, and a check fire at the end to make sure nothing on the new face runs hot. If the picture you liked cannot be built within the label, we show you the closest version that can.

Work like this goes faster when the fireplace type is settled first. Owners who plan to keep burning wood keep the existing box if it is sound. Owners who rarely burn wood often switch to gas at the same time, either with a log set listed for the unit or with an insert, and that choice changes the face, since inserts come with their own surround panels. Owners selling soon sometimes want only the face refreshed and the firebox checked, so a buyer's inspector finds a clean fireplace that matches its label. Each of those is a different scope and a different figure, and we price the one you choose. Book a visit through the contact page with a rough idea of the look you want and whether the fireplace burns wood, gas or nothing at all right now.

How Hurley Chimney Works Handles Each Job

Label Read First

Maker and model noted before any part is chosen

Listed Parts

Caps, panels and pipe the unit was tested with

Price Before Work

Each part and its cost written down first

Photo Report

Pictures of what we found, left with you

Related Fireplace Services

Chimney Sweep

Round metal pipe or square clay tile cleared from the firebox to the cap, with the spark screen scrubbed and a creosote grade noted.

Scope and parts →

Chimney Inspection

A Level 1 look at firebox, pipe, chase top and cap, read against the maker's install manual where one can be found.

Scope and parts →

Chimney Repair

Fixes for prefab and brick chimneys alike, with metal systems repaired using parts the maker lists for that model.

Scope and parts →

Fireplace Inspection

Metal firebox, refractory panels, doors, screen, damper and the trim around them, checked against the unit's listing label.

Scope and parts →

Fireplace Repair

Cracked panels, failed dampers, warped grates and loose doors on metal fireplaces, replaced with parts listed for the model.

Scope and parts →

Chimney Level 2 Inspection

Camera through every pipe section and a look inside the chase, for a sale, after a quake or flue fire, or with a fuel switch.

Scope and parts →

Chimney Cap Installation

Terminations made for your pipe brand and diameter, or a measured cap for brick flues, each with a spark screen.

Scope and parts →

Chimney Flashing Repair

Roof seals renewed where a framed chase or brick stack meets the shingles and rain has found a path past the old metal.

Scope and parts →

Chimney Masonry Repair

Brick, mortar and stone work on masonry stacks and on the veneer faces built around prefab fireplaces.

Scope and parts →

Chimney Rebuilds

A failed brick stack relaid, or a rotted framed chase reframed and resided around new listed pipe.

Scope and parts →

Fireplace Cleaning

Ash, soot and glass film cleared from metal fireplaces without scratching the panels or the box lining.

Scope and parts →

Gas Fireplace Cleaning

Burner, pilot, logs and fixed glass serviced on sealed gas units, with the outside vent termination looked at too.

Scope and parts →

Gas Fireplace Repair

Diagnosis on sealed gas fireplaces with a dead pilot, a weak flame or a remote that no longer answers.

Scope and parts →

Fireplace Inserts

Gas inserts for worn prefab boxes or brick openings, where the listing allows, each vented with its own liner.

Scope and parts →

Pellet Stove Repair

Jams, failed starts and shutdowns on freestanding and insert pellet units, followed back to the part at fault.

Scope and parts →

Wood Stove Repair

Seals, baffles, firebrick and pipe on freestanding stoves and wood inserts, refitted from the stove maker's parts list.

Scope and parts →

Gas Logs

Log sets for wood-burning prefab boxes, fitted only when the fireplace manual allows gas logs in that model.

Scope and parts →

Chimney Seismic Retrofit

Bracing or a lighter top for brick chimneys on older homes; metal pipe in a framed chase rarely needs it.

Scope and parts →

Chimney Crown Repair

Cracked mortar tops on brick stacks sealed or recast; framed chases use a metal lid, covered on its own page.

Scope and parts →

Dryer Vent Cleaning

Lint cleared from the duct between dryer and hood, with the flap at the outside wall or roof freed up.

Scope and parts →

Chimney Liner Installation

Stainless liners for brick flues with cracked tile, and listed replacement pipe where a prefab flue has failed.

Scope and parts →

Chimney Leak Repair

Water on a ceiling, wall or firebox floor traced to the chase top, cap, flashing or siding, then fixed at the source.

Scope and parts →

Chimney Waterproofing

Breathable repellent for brick chimneys, and sealing of siding, trim and seams on framed chases.

Scope and parts →

Chimney Damper Repair

Rusted, stuck or warped dampers on metal and brick fireplaces, mended with matching parts or a cap-mounted unit.

Scope and parts →

Chimney Chase Cover

Rusted or dished lids on framed chases replaced with stainless made to fit, sloped and edged to shed water.

Scope and parts →
Call (626) 557-0322